allplex rp 2 Search Results


90
BioFire Defense allplex rp 3
Comparison of the <t>Allplex</t> RP 1, 2, 3, and the BioFire FilmArray RP assays for the detection of respiratory viruses in nasopharyngeal swab (NPS) specimens (n = 181). ND: No virus detected.
Allplex Rp 3, supplied by BioFire Defense, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/allplex rp 3/product/BioFire Defense
Average 90 stars, based on 1 article reviews
allplex rp 3 - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
BioFire Defense allplex rp 2 assay
Comparison of the <t>Allplex</t> RP 1, 2, 3, and the BioFire FilmArray RP assays for the detection of respiratory viruses in nasopharyngeal swab (NPS) specimens (n = 181). ND: No virus detected.
Allplex Rp 2 Assay, supplied by BioFire Defense, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/allplex rp 2 assay/product/BioFire Defense
Average 90 stars, based on 1 article reviews
allplex rp 2 assay - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
BioFire Defense adenovirus nps specimens
Comparison of the <t>Allplex</t> RP 1, 2, 3, and the BioFire FilmArray RP assays for the detection of respiratory viruses in nasopharyngeal swab (NPS) specimens (n = 181). ND: No virus detected.
Adenovirus Nps Specimens, supplied by BioFire Defense, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/adenovirus nps specimens/product/BioFire Defense
Average 90 stars, based on 1 article reviews
adenovirus nps specimens - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Seegene Technologies allplex™ respiratory panel assays
Comparison of the <t>Allplex</t> RP 1, 2, 3, and the BioFire FilmArray RP assays for the detection of respiratory viruses in nasopharyngeal swab (NPS) specimens (n = 181). ND: No virus detected.
Allplex™ Respiratory Panel Assays, supplied by Seegene Technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/allplex™ respiratory panel assays/product/Seegene Technologies
Average 90 stars, based on 1 article reviews
allplex™ respiratory panel assays - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Seegene Technologies allplex rp1 kit
Comparison of the <t>Allplex</t> RP 1, 2, 3, and the BioFire FilmArray RP assays for the detection of respiratory viruses in nasopharyngeal swab (NPS) specimens (n = 181). ND: No virus detected.
Allplex Rp1 Kit, supplied by Seegene Technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/allplex rp1 kit/product/Seegene Technologies
Average 90 stars, based on 1 article reviews
allplex rp1 kit - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

Image Search Results


Comparison of the Allplex RP 1, 2, 3, and the BioFire FilmArray RP assays for the detection of respiratory viruses in nasopharyngeal swab (NPS) specimens (n = 181). ND: No virus detected.

Journal: Diagnostics

Article Title: Comparative Evaluation of Allplex Respiratory Panels 1, 2, 3, and BioFire FilmArray Respiratory Panel for the Detection of Respiratory Infections

doi: 10.3390/diagnostics12010009

Figure Lengend Snippet: Comparison of the Allplex RP 1, 2, 3, and the BioFire FilmArray RP assays for the detection of respiratory viruses in nasopharyngeal swab (NPS) specimens (n = 181). ND: No virus detected.

Article Snippet: The most frequently detected viral analytes in NPS specimens were HEV/HRV, where Allplex RP 2 and 3 assays detected 24 HEV and 55 HRV, while the BioFire FilmArray RP assay detected 39 HEV/HRV-positive samples.

Techniques: Comparison, Virus

Comparison of  Allplex RP  1, 2, 3 and BioFire FilmArray RP assays for the detection of respiratory viruses in NPS specimens.

Journal: Diagnostics

Article Title: Comparative Evaluation of Allplex Respiratory Panels 1, 2, 3, and BioFire FilmArray Respiratory Panel for the Detection of Respiratory Infections

doi: 10.3390/diagnostics12010009

Figure Lengend Snippet: Comparison of Allplex RP 1, 2, 3 and BioFire FilmArray RP assays for the detection of respiratory viruses in NPS specimens.

Article Snippet: The most frequently detected viral analytes in NPS specimens were HEV/HRV, where Allplex RP 2 and 3 assays detected 24 HEV and 55 HRV, while the BioFire FilmArray RP assay detected 39 HEV/HRV-positive samples.

Techniques: Comparison

Cycle threshold (Ct) values of viruses detected in NPS specimens by the Allplex RP 1, 2, 3 assays. The Allplex RP assays generate Ct values of respiratory pathogens, which were accepted as correct and utilized to compare the performance against the BioFire FilmArray RP. The BioFire FilmArray RP assay does not differentiate between HEV and HRV as well as RSV-A, and RSV-B, and reports them as a single analyte HEV/HRV and RSV-A/RSV-B, respectively. The NPS specimens were ordered by ascending Ct values. Blue symbols denote NPS specimens positive on Allplex RP but negative on the BioFire FilmArray RP.

Journal: Diagnostics

Article Title: Comparative Evaluation of Allplex Respiratory Panels 1, 2, 3, and BioFire FilmArray Respiratory Panel for the Detection of Respiratory Infections

doi: 10.3390/diagnostics12010009

Figure Lengend Snippet: Cycle threshold (Ct) values of viruses detected in NPS specimens by the Allplex RP 1, 2, 3 assays. The Allplex RP assays generate Ct values of respiratory pathogens, which were accepted as correct and utilized to compare the performance against the BioFire FilmArray RP. The BioFire FilmArray RP assay does not differentiate between HEV and HRV as well as RSV-A, and RSV-B, and reports them as a single analyte HEV/HRV and RSV-A/RSV-B, respectively. The NPS specimens were ordered by ascending Ct values. Blue symbols denote NPS specimens positive on Allplex RP but negative on the BioFire FilmArray RP.

Article Snippet: The most frequently detected viral analytes in NPS specimens were HEV/HRV, where Allplex RP 2 and 3 assays detected 24 HEV and 55 HRV, while the BioFire FilmArray RP assay detected 39 HEV/HRV-positive samples.

Techniques: RP Assay

Comparison of the Allplex RP 1, 2, 3, and the BioFire FilmArray RP assays for the detection of respiratory viruses in nasopharyngeal swab (NPS) specimens (n = 181). ND: No virus detected.

Journal: Diagnostics

Article Title: Comparative Evaluation of Allplex Respiratory Panels 1, 2, 3, and BioFire FilmArray Respiratory Panel for the Detection of Respiratory Infections

doi: 10.3390/diagnostics12010009

Figure Lengend Snippet: Comparison of the Allplex RP 1, 2, 3, and the BioFire FilmArray RP assays for the detection of respiratory viruses in nasopharyngeal swab (NPS) specimens (n = 181). ND: No virus detected.

Article Snippet: HEV and HRV have been reported separately by the Allplex RP 2 and 3 assays, whereas the BioFire FilmArray RP assay does not differentiate between them and reports as a single human rhinovirus/enterovirus (HRV/HEV).

Techniques: Comparison, Virus

Comparison of  Allplex RP  1, 2, 3 and BioFire FilmArray RP assays for the detection of respiratory viruses in NPS specimens.

Journal: Diagnostics

Article Title: Comparative Evaluation of Allplex Respiratory Panels 1, 2, 3, and BioFire FilmArray Respiratory Panel for the Detection of Respiratory Infections

doi: 10.3390/diagnostics12010009

Figure Lengend Snippet: Comparison of Allplex RP 1, 2, 3 and BioFire FilmArray RP assays for the detection of respiratory viruses in NPS specimens.

Article Snippet: HEV and HRV have been reported separately by the Allplex RP 2 and 3 assays, whereas the BioFire FilmArray RP assay does not differentiate between them and reports as a single human rhinovirus/enterovirus (HRV/HEV).

Techniques: Comparison

Cycle threshold (Ct) values of viruses detected in NPS specimens by the Allplex RP 1, 2, 3 assays. The Allplex RP assays generate Ct values of respiratory pathogens, which were accepted as correct and utilized to compare the performance against the BioFire FilmArray RP. The BioFire FilmArray RP assay does not differentiate between HEV and HRV as well as RSV-A, and RSV-B, and reports them as a single analyte HEV/HRV and RSV-A/RSV-B, respectively. The NPS specimens were ordered by ascending Ct values. Blue symbols denote NPS specimens positive on Allplex RP but negative on the BioFire FilmArray RP.

Journal: Diagnostics

Article Title: Comparative Evaluation of Allplex Respiratory Panels 1, 2, 3, and BioFire FilmArray Respiratory Panel for the Detection of Respiratory Infections

doi: 10.3390/diagnostics12010009

Figure Lengend Snippet: Cycle threshold (Ct) values of viruses detected in NPS specimens by the Allplex RP 1, 2, 3 assays. The Allplex RP assays generate Ct values of respiratory pathogens, which were accepted as correct and utilized to compare the performance against the BioFire FilmArray RP. The BioFire FilmArray RP assay does not differentiate between HEV and HRV as well as RSV-A, and RSV-B, and reports them as a single analyte HEV/HRV and RSV-A/RSV-B, respectively. The NPS specimens were ordered by ascending Ct values. Blue symbols denote NPS specimens positive on Allplex RP but negative on the BioFire FilmArray RP.

Article Snippet: HEV and HRV have been reported separately by the Allplex RP 2 and 3 assays, whereas the BioFire FilmArray RP assay does not differentiate between them and reports as a single human rhinovirus/enterovirus (HRV/HEV).

Techniques: RP Assay

Comparison of the Allplex RP 1, 2, 3, and the BioFire FilmArray RP assays for the detection of respiratory viruses in nasopharyngeal swab (NPS) specimens (n = 181). ND: No virus detected.

Journal: Diagnostics

Article Title: Comparative Evaluation of Allplex Respiratory Panels 1, 2, 3, and BioFire FilmArray Respiratory Panel for the Detection of Respiratory Infections

doi: 10.3390/diagnostics12010009

Figure Lengend Snippet: Comparison of the Allplex RP 1, 2, 3, and the BioFire FilmArray RP assays for the detection of respiratory viruses in nasopharyngeal swab (NPS) specimens (n = 181). ND: No virus detected.

Article Snippet: For adenovirus, Allplex RP 2 detected 31 NPS specimens versus 34 by the BioFire FilmArray assay.

Techniques: Comparison, Virus

Comparison of  Allplex RP  1, 2, 3 and BioFire FilmArray RP assays for the detection of respiratory viruses in NPS specimens.

Journal: Diagnostics

Article Title: Comparative Evaluation of Allplex Respiratory Panels 1, 2, 3, and BioFire FilmArray Respiratory Panel for the Detection of Respiratory Infections

doi: 10.3390/diagnostics12010009

Figure Lengend Snippet: Comparison of Allplex RP 1, 2, 3 and BioFire FilmArray RP assays for the detection of respiratory viruses in NPS specimens.

Article Snippet: For adenovirus, Allplex RP 2 detected 31 NPS specimens versus 34 by the BioFire FilmArray assay.

Techniques: Comparison

Cycle threshold (Ct) values of viruses detected in NPS specimens by the Allplex RP 1, 2, 3 assays. The Allplex RP assays generate Ct values of respiratory pathogens, which were accepted as correct and utilized to compare the performance against the BioFire FilmArray RP. The BioFire FilmArray RP assay does not differentiate between HEV and HRV as well as RSV-A, and RSV-B, and reports them as a single analyte HEV/HRV and RSV-A/RSV-B, respectively. The NPS specimens were ordered by ascending Ct values. Blue symbols denote NPS specimens positive on Allplex RP but negative on the BioFire FilmArray RP.

Journal: Diagnostics

Article Title: Comparative Evaluation of Allplex Respiratory Panels 1, 2, 3, and BioFire FilmArray Respiratory Panel for the Detection of Respiratory Infections

doi: 10.3390/diagnostics12010009

Figure Lengend Snippet: Cycle threshold (Ct) values of viruses detected in NPS specimens by the Allplex RP 1, 2, 3 assays. The Allplex RP assays generate Ct values of respiratory pathogens, which were accepted as correct and utilized to compare the performance against the BioFire FilmArray RP. The BioFire FilmArray RP assay does not differentiate between HEV and HRV as well as RSV-A, and RSV-B, and reports them as a single analyte HEV/HRV and RSV-A/RSV-B, respectively. The NPS specimens were ordered by ascending Ct values. Blue symbols denote NPS specimens positive on Allplex RP but negative on the BioFire FilmArray RP.

Article Snippet: For adenovirus, Allplex RP 2 detected 31 NPS specimens versus 34 by the BioFire FilmArray assay.

Techniques: RP Assay